Differential relay settings as protection on a 52 MVA Unit 4 Power Transformer PLTA Singkarak

Penyetingan Rele Differensial Sebagai Proteksi Pada Transformator Daya 52 MVA Unit 4 PLTA Singkarak

Authors

  • M. Rafli Ardiansyah UIN Suska Riau

DOI:

https://doi.org/10.57152/ijeere.v4i1.1405

Keywords:

Setting, Mathematical Calculations, Power Transformer, Differential Relay, Protection

Abstract

The protection system for electrical equipment is used to identify any disturbances and monitor any damage that may occur such as there is a difference between the incoming/primary and outgoing/secondary currents, and other electrical disturbances. One of them is the power transformer, of course the impact of these disturbances, if not resolved, will disrupt the power system at the plant. Then one solution is to use a protection device in the form of a differential relay. The purpose of preparing this report is to set up selective differential relays on power transformers. The method used in this report is manual and mathematical calculations on CT ratios, mismatch errors, restrain currents, differential currents, setting currents, CT secondary currents, and percent slope. After doing the mathematical calculations, we get the differential relay current setting, which is 0.21 A. The factory default setting is 0.3 A, or 30%, with the following assumptions: 10% for current transformer (CT), 1% for excitation settings , 4% for setting mismatch, 5% for safety factor, and 10% for setting leads. Differential Relay can function when the differential current is greater than the setting current; in this case, the relay will cause the circuit breaker to trip.

References

Andreas Hendratmoko. Analisis Kinerja Proteksi Relai Diferensial Pada Transformator Daya Di Gardu Induk 150 Kv Blora Menggunakan Software Etap 12.6.0. Universitas Muhammadiyah Surakarta 2021: 7 - 13.

Arief Goeritno, Syofyan Rasiman, Irwan Nugraha, Ayumi Johan. Kinerja Relai Diferensial Diukur Melalui Pemberian Simulasi Fenomena Gangguan Internal Pada Transformator Daya. Universitas Sultan Ageng Tritayasa 2020; 2: 179 - 181.

Elvy Sahnur Nasution, Faisal Irsan Pasaribu, Muhammad Arfianda. Rele Diferensial Sebagai Proteksi Pada Transformator Daya Pada Gardu Induk. Universitas Muhammadiyah Sumatera Utara 2018; 7.

Erwin dan Kiswondo, Dasar - Dasar Proteksi. PLN University.

Zulkarnaini, Fauza Hafni. Studi Analisa Rele Differensial Pada Proteksi Transformator 60 MVA Gardu Induk Pauh Limo. Institut Teknologi Padang 2020; 9.

R. Aita Diantari, T. Mardhi Rahmatullah, T. Elektro, dan S. Tinggi Teknik -PLN, “Analisa Proteksi Differensial Pada Generator Di Pltu Suralaya,” 2017.

Sekretariat Perusahaan. Company Profile PT PLN (Persero). PT PLN (Persero) PLTA SINGKARAK 2021

A. Multi dan T. Addaus, “PT. PLN (Persero) Distribusi Jawa Barat dan Banten Area Pelayanan dan Jaringan (APJ) Karawang Studi Analisis Gangguan Transformator Distribusi Pada Jaringan Distribusi 20 KV” vol. 32, hlm. 1–8, 2022, doi:10.37277/stch.v32i1.

Istimaroh, Anaa, Hariyanto, Nasrun. Teknik Elektro, Itenas Bandung. “Penentuan Setting Rele Arus Lebih Generator Dan Rele Diferensial Transformator Unit 4 PLTA CIRATA II” . 2013

Syaputra, Julian. T.Elektro, “Analisa Penyetelan Rele Arus Lebih Untuk Pengaman Transformator Pemakaian Sendiri 9mva, 11 Kv/6 Kv Unit 4 Pt. PLN (Persero) Sektor Pembangkitan Bukit Asam”

Ulfah, Nurida Maharani, Trihasto, Agung, Pravitasari, Deria. THETA OMEGA: Journal of Electrical Engineering, Computer, and Information Technology “Evaluasi Kinerja Rele Arus Lebih Dan Rele Diferensial Pada Generator Kapasitas 100 MW”. 2021

Published

2024-06-27

How to Cite

[1]
M. R. Ardiansyah, “Differential relay settings as protection on a 52 MVA Unit 4 Power Transformer PLTA Singkarak: Penyetingan Rele Differensial Sebagai Proteksi Pada Transformator Daya 52 MVA Unit 4 PLTA Singkarak”, IJEERE, vol. 4, no. 1, pp. 01-08, Jun. 2024.

Issue

Section

Table of Contents IJEERE