In-depth Study of Partial Discharge in Power Transformers: Challenges and Analysis Selected Articles
Studi Mendalam tentang Partial Discharge pada Transformator Daya: Tantangan dan Analisis Artikel Terpilih
DOI:
https://doi.org/10.57152/ijeere.v4i1.1477Keywords:
Detection, Method, Partial Discharge, Sensor, Power TransformatorAbstract
Partial discharge (PD) is an electrical phenomenon that occurs in the insulation of a power transformer when high voltage causes the release of small amounts of electrical energy. Although PD itself does not directly cause damage, this phenomenon can gradually damage the insulation, reduce its effectiveness, and eventually lead to transformer failure if not detected and addressed. PD usually indicates a weakness or defect in the insulation system, such as an air gap, contamination, or damage to the insulation material. This article reviews recent research on PD in power transformers published since 2020 and selects some dominant studies for further analysis. The article identifies challenges in PD detection and analysis, such as sensor sensitivity, signal interference, and the need for more accurate diagnosis methods.
References
M. Azadifar et al., “Partial discharge localization using electromagnetic time reversal: A performance analysis,” IEEE Access, vol. 8, pp. 147507–147515, 2020.
M. Aslam, M. S. Rehan, F. R. Albogamy, S. Murawwat, A. Basit, and G. Hafeez, “Prognostication of Failures Using Signal-to-Noise Ratio to Determine Partial Discharges Activities in Power Transformers,” IEEE Access, vol. 10, pp. 87500–87507, 2022.
V. Malažinskas et al., “Evaluation of the insulation condition of high-voltage transformers by detecting partial discharges using the electromagnetic wave radiation method,” Materials and Technology, vol. 55, no. 2, pp. 253–261, 2021.
M. Kunicki, “Analysis on acoustic disturbance signals expected during partial discharge
measurements in power transformers,” Archives of Acoustics, vol. 45, no. 4, 2020.
L. Damião et al., “Online monitoring of partial discharges in power transformers using capacitive
coupling in the tap of condenser bushings,” Energies (Basel), vol. 13, no. 17, p. 4351, 2020.
M. A. Azirani, M. Ariannik, P. Werle, and A. Akbari, “Optimal frequency selection for detection of partial discharges in power transformers using the UHF measurement technique,” Measurement, vol. 172, p. 108895, 2021.
T. Mariprasath and M. Ravindaran, “An experimental study of partial discharge analysis on environmental friendly insulating oil as alternate insulating material for transformer,” S?dhan?, vol. 47, no. 4, p. 204, 2022.
M. Florkowski and M. Kuniewski, “Partial Discharge-Originated Deterioration of Insulating Material Investigated by Surface-Resistance and Potential Mapping,” Energies (Basel), vol. 16, no. 16, p. 5973, 2023.
H. Besharatifard, S. Hasanzadeh, E. Heydarian-Forushani, H. H. Alhelou, and P. Siano, “Detection and analysis of partial discharges in oil-immersed power transformers using low-cost acoustic sensors,” Applied Sciences, vol. 12, no. 6, p. 3010, 2022.
Y. Li and Z. Tang, “Research on the propagation characteristics of high frequency partial discharge
signal in transformer,” in Journal of physics: conference series, IOP Publishing, 2022, p. 012066.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Furqon M.Chaisar Al Furqon