Abstract

The generator is one of the main components in the Teluk Sirih PLTU as a producer of electricity that will be supplied to consumers. The generator itself is not spared from existing disturbances. One of the disturbances that can occur in a generator is an overcurrent disturbance caused by a short circuit. Therefore the generator must be given a protection, namely an overcurrent relay which is useful for giving a signal to the PMT to open the circuit. In this report, we will test the performance of the overcurrent relay installed on the generator by looking for settings based on a 3-phase short circuit fault in one of the bus areas. The data used is in the form of Generator, Transformer and Overcurrent Relay specification data. Then from the data a series will be made and simulated using the ETAP 19.0.1 application. Based on the simulation that has been carried out, it is found that the magnitude of the 3-phase short circuit fault current in the Bus 2 area is 41501 A. Meanwhile for the overcurrent relay setting, the relay current is 3.39 A, the set current in the relay setting is 5982.757 A and the time is 0.34 s with a CT ratio of 1600:1. The result obtained is that the relay works according to the existing settings when a fault occurs and instructs the PMT to open the circuit.

References

H. Abbas, J. Jamaluddin, and A. Amiruddin, “Analisa Pembangkit Tenaga Listrik Dengan Tenaga Uap Di PLTU,” ILTEK?: Jurnal Teknologi, vol. 15, no. 02, pp. 103–106, Oct. 2020, doi: 10.47398/iltek.v15i02.33.

A. V. Yunitasari and S. Pramono, “Sistem Proteksi Over Current Relay Motor Forced Draft Fan pada Pembangkit Listrik Tenaga Uap,” vol. 13, no. 1, 2021, doi: 10.24853/jurtek.13.1.55-62.

Z. Zulkarnaini, “Analisa Proteksi Arus Lebih Pada Generator PLTU Teluk Sirih,” Jurnal Teknik Elektro ITP, vol. 8, no. 1, pp. 28–34, Jan. 2019, doi: 10.21063/jte.2019.3133806.

U. Pembangkitan et al., “Analisis Energi Hilang Akibat Gangguan pada Pembangkit di PT. PJB,” 2018.

S. Bandri, “Analisa Pengaruh Perubahan Beban Terhadap Karakteristik Generator Sinkron (Aplikasi PLTG Pauh Limo Padang),” Jurnal Teknik Elektro, vol. 2, pp. 42–48, 2018.

Erwin and Kiswondo, Dasar - Dasar Proteksi. PLN University.

S. Nurhadiyono, N. Efendi, and P. Studi Teknik Elektro Sekolah Tinggi Teknik Wiworotomo Purwokerto Jalan Semingkir No, “Analisis Setting Relay Proteksi Pengaman Arus Lebih Pada Generator (Studi Kasus di PLTU 2X300 MW Cilacap),” 2018.

R. Aita Diantari, T. Mardhi Rahmatullah, T. Elektro, and S. Tinggi Teknik -PLN, “Analisa Proteksi Differensial pada Generator di PLTU Suralaya,” 2017.

A. Multi and T. Addaus, “Analisa Proteksi Over Current Relay (OCR) dan Ground Fault Relay (GFR) pada Transformator Daya Gardu Induk,” pp. 1–8, 2022, doi: 10.37277/stch.v32i1.

A. W. Hidayat, H. Gusmedi, L. Hakim, and D. Despa, “Analisa Setting Rele Arus Lebih dan Rele Gangguan Tanah pada Penyulang Topan Gardu Induk Teluk Betung,” Jurnal Rekayasa dan Teknologi Elektro, vol. 7, no. 3, 2021.

L. Shintawaty, “Sistem Proteksi Pada Generator di PLTG Musi 2 Palembang,” Jurnal Desiminasi Teknologi, vol. 2, no. 1, pp. 1–12, 2019.

I. Operation Technology, “ETAP User Guide,” 2019.

M. Tugas Akhir Disusun Oleh, “Perbandingan Metode Gauss-Seidel, Metode Newton Raphson Dan Metode Fast Decoupled Dalam Solusi Aliran Daya.”

R. Aita Diantari, T. Mardhi Rahmatullah, T. Elektro, and S. Tinggi Teknik -PLN, “Analisa Proteksi Differensial Pada Generator di PLTU Suralaya,” Jurnal Energi & Kelistrikan, vol. 9, no. 1, pp. 84–92, 2019.

A. Akmal et al., “Studi Pengaturan Relay Arus Lebih Dan Relay Hubung Tanah Penyulang Timor 4 Pada Gardu Induk Studi kasus?: Gardu Induk Dawuan,” JURNAL INFOTRONIK, vol. 2, no. 1, 2017.

Published

2023-12-27

How to Cite

[1]
R. Saputra, “Analysis Of The Use Of Overcurrent Protection In Generator Case Study Of Teluk Sirih PLTU : Analisis Penggunaan Proteksi Arus Lebih Pada Generator Studi Kasus PLTU Teluk Sirih”, IJEERE, vol. 3, no. 2, pp. 112-123, Dec. 2023.

Issue

Section

Table of Contents IJEERE